USP <788>, <787> and EP2.9.19
Defining allowable limits of sub-visible particulates in parenteral formulations
Chapters <788> and <787> of the United States Pharmacopeia (USP), Particulate Matter in Injections, and chapter 2.9.19 of the European Pharmacopoeia apply to most small- and large-volume parenteral products, particularly ready-to-use solutions for intramuscular, subcutaneous or intravenous (IV) injection.
USP defines particulate matter as mobile undissolved particles, other than gas bubbles, unintentionally present in the solutions. Further, it provides 2 tests for detecting subvisible particulates—light obscuration technology and microscopic assay. USP<788>, <787> and EP2.9.19 are harmonized and state a preference for using the light obscuration counter, deferring only to the microscopic method when the light obscuration instrument cannot be used for some reason. These instruments are generally accepted for use in testing:
- Small-volume parenteral infusions/injectables (ampules and vials)
- Large-volume parenteral infusions/injectables (IV solutions)
Although light obscuration technology is generally the preferred testing method, it may be necessary to test some formulations using light obscuration and a microscopic particle count test to confirm compliance with applicable requirements.
Note that USP <788> does not apply for:
- Radiopharmaceutical preparations
- Parenterals for use only as irrigating solutions
- Parenterals requiring use of a filter prior to administration (provided scientific data justifies an exemption)
Helpful Links
-
Normes de l’industrie
- USP<643>
-
21 CFR Part 11 - Data Integrity
- 21 CFR Part 11 Related Products: Instruments for Data Integrity and Compliance
- 21 CFR Part 11: Scope and Application
- Centrifugation That Supports 21 CFR Part 11 Compliance
- Équivalents mondiaux et règlements connexes
- Améliorer l’intégrité de vos documents électroniques
- 21 CFR Part 11 - Terms and Acronyms
- Maintaining Data Integrity: Understanding FDA ALCOA Guidance
- European Pharmacopoeia EP 2.2.44
- EU GMP Annex 1
- EU GMP Annex 11
- ICH Q2
- ISO 21501
- ISO Regulations
-
Réglementation sur les DIV (IVDR)
- IVDR compliant instruments*
- IVDR compliant software*
- IVDR compliant reagents
- E-book
- Future proofing your flow cytometry panel under IVDR
- Panel de FCM de DIV interne ou non : tout dépend
- Building IVDR compliant panels for haematological disorders
- Webinaire sur l'impact du nouveau règlement UE IVDR sur le quotidien des laboratoires de cytométrie en flux clinique
- Test développé en laboratoire (TDL) vs flux de travail de validation du DIV
- Rencontre avec un expert — Dr Maurizio Suppo
- Impacts potentiels du règlement UE IVDR sur le laboratoire de cytométrie en flux clinique
- Annex I Global Safety and Performances Requirements
- IVDR : considérations essentielles pour valider une analyse de cytométrie en flux conformément aux exigences de la norme ISO 15189
- Regulatory Entities: Separation with Cooperation
- USP 1046
- USP 1047
- USP <788>, <787> and EP2.9.19
- USP <790>
- Norme ISO 11171
-
ISO 14644 : Propreté des particules aéroportées dans les salles blanches et les zones propres
- Compteurs de particules conçus pour répondre aux exigences des normes ISO 14644-1 et ISO 21501-4
- Normes publiées en 2015 pour ISO 14644
- ISO 14644-1 Classification de la propreté de l’air par la concentration des particules
- ISO 21501-4 : Compteur de particules aéroportées par diffraction lumineuse pour les espaces propres
- Comptage de particules : Termes et formules
-
USP <787>
- USP <787> : Solutions de test des particules pour le contrôle de la contamination
- Obscurcissement : méthode optique de détection des particules
- USP <787> : Particules imperceptibles dans des injections de protéine thérapeutique
- USP <787> : Application et portée
- Exigences des salles blanches pour les tests des particules liquides